Ground Source Heat Pump for Houses Heating and Hot Water
Ground Source Heat Pump for Houses Heating and Hot Water
Introduction:
Ground Source Heat Pump, Water to Water Heat Pump for Residence Heating, Domestic Hot Water and Cooling
-For air conditioning Heating: Floor Heating, Radiator Heating, Fan Coil Heating etc.
-Providing Domestic Hot Water 40-70°C;
-Using groundwater, surface water etc open loop. or geothermal heat energy close loop etc. to be as the heat resource to saving energy;
-Multifunction: In winter for Heating and hot water, in summer for Cooling and free hot water;
-For Houses, Villas, Hotels etc. buildings to replace boiler to saving money.
MODELS: LTWH(R)-020---LTWH(R)-100
Heating Capacity: 8.6-41KW; Cooling Capacity: 7.2-37KW
1.Cooling Standard Conditions:User side water inlet/outlet 12°C/7°C;Water source side inlet/outlet 30°C/35°C.
2.Heating Standard Conditions: User side hot water inlet/outlet 40°C/45°C;Water source side inlet/outlet 15°C/7°C;
3.Heat recovery equipments can be added for free sanitary hot water.
Features
STRUCTURE
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
HERMETIC COMPRESSORS
380V/3P/50(60)HZ or 220V/1P/50(60)HZ world famous brand hermetic scroll compressors.
EVAPORATOR
High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material.
CONDENSER
High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material.
REFRIGERANT CIRCUIT
Copper tube connection with charge valves, filter, thermostatic expansion valve (capillary for mod. 4.5÷14), gas-liquid separator, high pressure switch and low pressure switch. The heat pump units are complete also with 4-way valve and one way valve.
HYDRAULIC CIRCUIT
Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve, mod.4.5÷30 the user side is complete also with expansion vessel, water pump and water flow switch.
ELECTRIC PANEL
Consists of: Compressor contactor, Compressor protection breaker,User side water pump contactor, User side water pump breaker, Microprocessor with function display
OPTIONAL
Sight glass which must be installed in factory,
Source side water flow switch,
Source side water pump,
Anti-vibration rubber,
Metallic filter for the water circuit.
Heat recovery for hot water as optional
Model Details:
Model Specifications:
Model No. LTWH(R)— | 020 | 025 | 030 | 035 | 040 | 050 | 060 | 065 | 075 | 090 | 100 | |||
Heating Capacity(KW) | 8.6 | 10.2 | 12.0 | 14.7 | 17.7 | 21.6 | 24.2 | 26.5 | 30.0 | 36.0 | 41.0 | |||
Cooling Capacity(KW) | 7.2 | 8.6 | 10.1 | 12.2 | 15.0 | 18.2 | 20.3 | 23.0 | 26.0 | 31.0 | 37.0 | |||
Electrical Parameters | Power | 3/N/PE AC220V/380V 50HZ | ||||||||||||
Input | Heating | kW | 1.9 | 2.3 | 2.7 | 3.4 | 4.0 | 4.7 | 5.3 | 6.1 | 6.9 | 7.9 | 9.5 | |
Power | Cooling | kW | 1.2 | 1.5 | 1.7 | 2.2 | 2.6 | 3.2 | 3.5 | 4.0 | 4.5 | 4.8 | 6.1 | |
Control System | Dedicated heat pump controller,PID regulator | |||||||||||||
Security | Overload, high voltage, wrong Phase, water, oil, antifreeze switch, high temperature protection | |||||||||||||
Compressor | Type | Flexible all closed scroll type | ||||||||||||
Quantity | set | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||
Refrigerant | Type | Environmental protection Refrigerants(R134A,R410A,R407C etc.) | ||||||||||||
Charge | kg | 1.4 | 1.6 | 2 | 2.2 | 2.7 | 3.2 | 3.7 | 4.2 | 4.8 | 5.7 | 6.8 | ||
Evaporator | Type | Efficient copper Tube in Tube Heat Exchanger | ||||||||||||
Water | Heating | m3/h | 1.7 | 2 | 2.4 | 2.9 | 3.5 | 4.3 | 4.8 | 5.2 | 6 | 7.2 | 8.3 | |
Flow | Cooling | m3/h | 1.4 | 1.7 | 2 | 2.4 | 3 | 3.6 | 4 | 4.6 | 5.2 | 6.2 | 7.4 | |
Pressure Loss | Kpa | ≤40 | ||||||||||||
Interface Dim. | DN(mm) | 25 | 25 | 25 | 32 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | ||
Condenser | Type | Efficient copper Tube in Tube Heat Exchanger | ||||||||||||
Water | Heating | m3/h | 1.4 | 1.7 | 2 | 2.4 | 3 | 3.6 | 4 | 4.6 | 5.2 | 6.2 | 7.4 | |
Flow | Cooling | m3/h | 1.7 | 2 | 2.4 | 2.9 | 3.5 | 4.3 | 4.8 | 5.2 | 6 | 7.2 | 8.3 | |
Pressure Loss | Kpa | ≤40 | ||||||||||||
Interface Dim. | DN(mm) | 25 | 25 | 25 | 32 | 32 | 32 | 40 | 40 | 40 | 50 | 50 | ||
Size | Length | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1100 | 1100 | 1100 | 1100 | 1200 | 1200 | |
Width | mm | 600 | 600 | 600 | 600 | 600 | 660 | 660 | 660 | 660 | 660 | 680 | ||
Height | mm | 800 | 800 | 850 | 850 | 850 | 880 | 880 | 880 | 880 | 880 | 880 | ||
Unit weight | kg | 140 | 140 | 150 | 180 | 220 | 260 | 280 | 300 | 350 | 420 | 490 | ||
Noise | dB(A) | <60 | <60 | <62 | ||||||||||
DHW System | Type | Circulation-type casing Tube in Tube Heat Exchanger | ||||||||||||
Water interface | mm | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 25 | 32 | ||
Hot water Volume | m3/h | 0.3 | 0.35 | 0.45 | 0.48 | 0.6 | 0.8 | 1 | 1.1 | 1.15 | 1.37 | 1.64 |
Ground Source Heat Pump for Houses Heating and Hot Water